ПОЛУГЕРМЕТИЧНЫЕ КОМПРЕССОРЫ серии STANDART Цены на полугерметичные поршневые компрессоры DL
Серия L
(R22) 50Hz / 50Гц

Рабочие характеристики
Компрессор Температура конденсации °C Температура кипения, °C
-50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 7 10 12,5
DLE-201 / -20X(1) Q 30   0.951.391.952.633.474.465.637.008.5710.3711.1612.4213.54
40    0.68 1.08 1.57 2.18 2.91 3.79 4.83 6.05 7.46 9.07 9.78 10.92 11.93
50    0.43 0.79 1.22 1.75 2.40 3.17 4.08 5.16 6.40 7.84 8.48 9.49 10.40
  P 30   0.97 1.121.271.421.561.691.791.861.901.901.881.841.79
40   0.911.091.271.461.651.831.992.132.242.312.332.342.34
50    0.841.041.251.481.711.932.152.342.522.672.712.782.81
DLF-201 / -20X(1) Q 30 0.530.871.351.972.743.684.816.147.689.46      
40  0.631.041.582.263.104.115.316.718.32     
50   0.751.211.812.543.444.51       
  P 30 0.851.031.231.441.651.872.062.242.382.48      
40  0.971.191.441.701.962.222.462.682.87     
50   1.131.411.712.022.332.64        
DLF-301 / -30X(1) Q 30   1.391.972.743.704.856.207.779.5511.5413.7714.7316.2317.56
40   1.061.572.253.104.145.356.758.3510.1612.1713.0314.3915.59
50   0.761.211.812.563.474.555.797.228.8310.6211.4012.6213.69
  P 30   1.231.441.651.862.052.232.372.462.512.492.462.402.32
40   1.191.431.691.952.202.432.642.822.953.023.033.033.00
50   1.141.401.691.992.302.592.863.113.323.483.533.583.60
DLJ-201 / -20X Q 30 0.631.011.562.293.214.335.67        
40 0.460.771.231.852.653.644.83        
50  0.550.911.432.122.984.03        
  P 30 0.941.131.351.601.852.092.32        
40 0.861.071.321.601.902.212.50        
50  0.991.261.571.912.272.63        
DLJ-301 / -30X(1) Q 30   1.652.333.224.335.677.229.0011.0013.2415.7116.7718.4319.88
40   1.261.852.643.624.816.197.789.5711.5713.7814.7316.2117.51
50   0.931.442.132.994.035.256.648.2310.0011.9612.7914.1115.26
  P 30   1.341.591.842.092.332.532.702.822.872.852.822.752.67
40   1.291.581.892.192.492.773.013.223.373.453.473.463.43
50   1.231.561.902.252.612.953.263.553.783.964.024.084.10
DLL-301 / -30X(1) Q 30 0.901.462.183.084.195.537.128.9911.1613.65     
40  1.081.722.533.524.726.167.85       
50    2.002.883.955.24        
  P 30 1.181.421.681.962.242.522.803.053.263.44     
40  1.391.682.012.352.713.073.41       
50    2.032.432.863.29        
DLL-401 / -40X(1) Q 30   2.243.104.215.587.219.1111.2813.7416.4819.5320.8322.8724.67
40   1.762.523.514.726.177.879.8112.0114.4717.2018.3720.2121.82
50    2.012.873.955.236.738.4510.3912.5815.0016.0417.6819.11
  P 30   1.711.982.262.542.803.043.243.393.493.513.493.443.37
40   1.712.022.352.693.033.353.653.914.124.274.314.344.35
50    2.042.422.823.223.624.014.374.694.965.055.165.24
DLSG-401 / -40X(1) Q 30 1.322.022.974.165.577.199.00        
40 1.031.622.463.514.786.247.89        
50    1.972.904.025.326.80         
  P 30 1.531.872.252.643.023.363.65        
40 1.441.832.272.733.193.624.01        
50    2.252.773.293.814.29         
DLHA-500 / -50X(2) Q 30   2.523.584.846.368.1710.2912.7815.6618.97     
40   1.552.564.155.537.169.0911.3513.9817.00     
50   1.031.933.004.746.217.949.98       
  P 30   2.392.813.233.654.054.434.775.065.30     
40   2.352.833.333.844.354.855.335.776.18     
50   2.282.813.383.984.595.205.81       

Q(kW) = Холодопроизводительность, кВт
P(kW) = Потребляемая мощность, кВт
Рабочие условия температура всасываемого газа 20°C

19.89ВЫСОКАЯ ТЕМПЕРАТУРА НАГНЕТАНИЯ – требуется дополнительное охлаждение
12.00Перегрев на всасывании 10К

(1) Компрессор с водяным охлаждением необходимо оснастить вентилятором с производительностью минимум 10 м3/мин.
(2) Только с воздушным охлаждением.